WeatherTech WeatherSeal Trowel-On

The following details can be downloaded directly from LaHabra Stucco in Autocad .DWG format. Simply click on the desired file and you will be prompted by your browser for file saving instructions.

 

Content Download Download Zip
WeatherTech WRBs Details Book
PDF  
General Construction
  • WRB 1.01 Sheathing Joint Treatment
PDF DWG
General Construction
  • WRB 1.02 On Masonry with Parex USA Stucco Level Coat
PDF DWG
General Construction
  • WRB 1.03 On Masonry
PDF DWG
Terminations at Foundations
  • WRB 1.04 Foundation
PDF DWG
Terminations at Foundations
  • WRB 1.05 Termination at Wall Base Flashing
PDF DWG
Terminations at Foundations
  • WRB 1.06 Termination at Foundation Flashing
PDF DWG
Terminations at Foundations
  • WRB 1.07 Termination at Stucco Wrap
PDF DWG
Terminations at Foundations
  • WRB 1.08 Termination at Through-Wall Flashing Foundation Masonry Ledge
PDF DWG
Terminations at Foundations
  • WRB 1.09 Termination at Through-Wall Flashing and Foundation
PDF DWG
Terminations at Foundations
  • WRB 1.10 Sidewalk Floorline Foundation
PDF DWG
Window and Door Terminations
  • WRB 1.11 Rough Opening Treatment
PDF DWG
Window and Door Terminations
  • WRB 1.12 Rough Opening Treatment
PDF DWG
Window and Door Terminations
  • WRB 1.13 Rough Opening Jamb & Sill
PDF DWG
Window and Door Terminations
  • WRB 1.13 Rough Opening Jamb & Sill
PDF DWG
Window and Door Terminations
  • WRB 1.14 Rough Opening Jamb & Sill
PDF DWG
Window and Door Terminations
  • WRB 1.15 Rough Opening Treatment
PDF DWG
Window and Door Terminations
  • WRB 1.16 Termination at Sill Pan Flashing End Dam
PDF DWG
Window and Door Terminations
  • WRB 1.17 Head Flashing
PDF DWG
Window and Door Terminations
  • WRB 1.18 Seal at Masonry Head Flashing
PDF DWG
Expansion Joints
  • WRB 1.19 Expansion Joint A
PDF DWG
Expansion Joints
  • WRB 1.20 Expansion Joint B
PDF DWG
Roofs
  • WRB 1.21 Floor Line Deflection Joints
PDF DWG
Roofs
  • WRB 1.22 Terminations at Roofs
PDF DWG
Roofs
  • WRB 1.23 Low Parapet High Wall Intersection
PDF DWG
Roofs
  • WRB 1.24 Low Parapet High Wall Intersection
PDF DWG
Roofs
  • WRB 1.25 Low Parapet High Wall Intersection
PDF DWG
Penetrations
  • WRB 1.26 Seal at Duct Penetration
PDF DWG
Penetrations
  • WRB 1.27 Seal at Pipe Penetration
PDF DWG
Penetrations
  • WRB 1.28 Typical Application at Brick Ties
PDF DWG
Transitions to Dissimilar Water-Resistive Barriers
  • WRB 1.29 Horizontal Transition to Non-Adhered Water-Resistive Barrier Sheet Above
PDF DWG
Transitions to Dissimilar Water-Resistive Barriers
  • WRB 1.30 Horizontal Transition to Non-Adhered Water-Resistive Barrier Sheet Above
PDF DWG
Transitions to Dissimilar Water-Resistive Barriers
  • WRB 1.31 Vertical Transition to Non-Adhered Water-Resistive Barrier Sheet Above
PDF DWG

 

 

Disclaimer: The design specifications and construction shall comply with all local building codes and standards.

 

Parex USA installation guidelines are for general information and guidance only and Parex USA specifically disclaims any liabilitY for the use of this design, and for design engineering, or workmanship of any project. The assembly shall be designed to prevent condensation within the assembly. The designer and the user shall provide final drawings and specifications. Products shown other than those manufactured by Parex USA are shown for clarity of the Parex USA product only. Contact the Manufacturer for installation instructions.

 

Note:
To ensure a continuous air barrier across the building envelope, a continuous air seal should be made at each substrate change, joints/gaps, penetrations and dissimilar material terminations. There must be a consideration of the Designer in the overall wall assembly design. Stucco claddings and any cladding using a mortar bed require the use of a slipsheet installed over the Water-Resistive & Air Barrier Coating to prevent adhesion to the stucco.